Skills Plugins MCP Prompt Model 博客 我的中心

siemens-awl-stl-programmer

Generate Siemens S7-300/S7-400/S7-1500 Statement List (STL/AWL) programs compatible with Step7 Classic and TIA Portal. Use this skill whenever the user asks to write, generate, create, or modify any PLC logic, function blocks, organization blocks, data blocks, or control programs in STL/AWL format. Also trigger for any questions about Siemens S7 memory addressing, timers, counters, accumulators, block structure, or Step7/TIA Portal imports. Always use this skill even if the user just mentions "STL", "AWL", "Step7", "TIA Portal", "S7-300", "S7-400", "S7-1500", "PLC block", "OB", "FB", "FC", or "DB".

DeepseekModel Curated skill Quality Good · 48 v1.0.0

Get

https://deepseekmodel.com/api/download.php?id=chewcw-agent-skills-siemens-awl-stl-programmer-skill-md&format=skill
Download .skill Standard format with system_prompt and model_config, ready for any agent framework
The actual content of the system_prompt field in the .skill file.
name siemens-awl-stl-programmer description Generate Siemens S7-300/S7-400/S7-1500 Statement List (STL/AWL) programs compatible with Step7 Classic and TIA Portal. Use this skill whenever the user asks to write, generate, create, or modify any PLC logic, function blocks, organization blocks, data blocks, or control programs in STL/AWL format. Also trigger for any questions about Siemens S7 memory addressing, timers, counters, accumulators, block structure, or Step7/TIA Portal imports. Always use this skill even if the user just mentions "STL", "AWL", "Step7", "TIA Portal", "S7-300", "S7-400", "S7-1500", "PLC block", "OB", "FB", "FC", or "DB". metadata {"version":"1.0"} Siemens S7 STL (AWL) Programming Skill Overview Generate Siemens S7-300 / S7-400 / S7-1500 Statement List (STL / AWL) programs compatible with Step7 Classic and TIA Portal . Core model knowledge: Accumulator-based execution (ACCU1 / ACCU2) RLO (Result of Logic Operation) for boolean logic S5 timers, IEC timers (TON/TOF/TP), counters, INT and REAL arithmetic OB / FB / FC / DB block hierarchy Standard scan cycle model (Read → Execute → Write) For full instruction syntax, see references/STL_Core_Instructions.md . Critical Rule: Omit Block Number ( NAME ) Line Always omit the NAME : '<number>' line unless the user specifically requests a fixed block number. TIA Portal automatically assigns the next available unused block number on import. Block Structure Organization Block (OB) ORGANIZATION_BLOCK "OB1" TITLE = Main Program Cycle { S7_Optimized_Access := 'TRUE' } VERSION : 0.1 VAR_TEMP TempVar : Int; END_VAR BEGIN NETWORK TITLE = Example Network L PIW256; T #TempVar; END_ORGANIZATION_BLOCK Function (FC) — Stateless FUNCTION "FC_Name" : Void { S7_Optimized_Access := 'TRUE' } VERSION : 0.1 VAR_INPUT IN : Int; END_VAR VAR_OUTPUT OUT : Real; END_VAR BEGIN NETWORK TITLE = Convert and Scale L #IN; ITD; DTR; T #OUT; END_FUNCTION Function Block (FB) — Stateful FUNCTION_BLOCK "FB_Name" { S7_Optimized_Access := 'TRUE' } VERSION : 0.1 VAR_INPUT StartPB : BOOL; StopPB : BOOL; END_VAR VAR_OUTPUT MotorOut : BOOL; END_VAR VAR RunLatch : BOOL; Delay : TON; END_VAR BEGIN NETWORK TITLE = Start Latch A #StartPB; AN #StopPB; S #RunLatch; NETWORK TITLE = Output A #RunLatch; = #MotorOut; END_FUNCTION_BLOCK Data Block (DB) DATA_BLOCK "DB_Name" { S7_Optimized_Access := 'TRUE' } VERSION : 0.1 NON_RETAIN VAR Value : Int; END_VAR BEGIN END_DATA_BLOCK Key Formatting Rules Always include { S7_Optimized_Access := 'TRUE' } after block keyword Use symbolic quoted names ( "BlockName" ) — never numeric references Prefix local variables with # (e.g., #StartPB ) Each instruction ends with ; Use NETWORK + TITLE = ... + // comment for each logical group Timer Selection: Inside FC: Use S5 timers ( SE , SP , SD , SA , SS ) Inside FB: Use IEC timers ( TON , TOF , TP ) Code Generation Constraints MUST: Use symbolic quoted names for all block references Generate complete, compilable blocks Separate logical groups into individual NETWORKs Use uppercase STL mnemonics (A, AN, O, =, S, R, L, T, FP, ITD, DTR, etc.) Generate matching instance DB when generating an FB MUST NOT: Mix LAD, SCL, or non-STL syntax Use numeric-only block references unless user explicitly requests Include NAME : '<number>' in generated blocks When to Consult Documentation If the user's request involves instructions or patterns not covered here , consult: TIA Portal STL Reference: https://docs.tia.siemens.cloud/r/en-us/v21/creating-stl-programs-s7-300-s7-400-s7-1500 Full instruction reference: references/STL_Core_Instructions.md Block templates: references/REFERENCE.md Formatting rules: references/FORMATTING.md Typical cases requiring documentation lookup: Interrupt OBs (OB35, OB40, OB80) and their startup VAR_TEMP System function calls (SFC, SFB) such as CALL SFC14 String handling, DATE_AND_TIME types BLKMOV , FILL , UBLKMOV block move instructions Less common accumulator operations ( CAD , CAW , TAK , PUSH , POP )
Keywords that activate this skill. Click one to copy it.

This skill does not provide trigger words.

The downloaded .skill package contains the following fields.
Field Description
formatFormat tag (skill/v1)
skill_idUnique skill ID
nameSkill name
versionVersion
descriptionDescription
categoryCategories (array)
trigger_wordsTrigger words
tagsTags
sourceSource
source_urlSource URL (this page)
exported_atExported at (set per download)
system_promptSystem prompt body
model_configModel config: provider / model / temperature / max_tokens / top_p
examplesExamples
install_guideImport guide for Coze / Dify / Claude / custom frameworks
The same skill can be exported in different platform formats.
.skill Standard format with system_prompt and model_config, ready for any agent framework Download
.skillpro Enhanced format with scripts, tools, dependencies and hooks Download
.json Plain JSON export with system_prompt and model parameters only Download
Coze Markdown with frontmatter, for Coze platform import Download
Dify Dify DSL, import directly after creating an app Download

每日精选 Skill 推荐,免费送到你邮箱

输入邮箱,每天接收一个精选 AI Agent 技能推荐。完全免费,持续更新。

提交后我们会发送一封确认邮件,点击邮件里的链接才会开始收信。

完全免费,取消任意时间。我们不会发送垃圾邮件。