内容创作
#data
siemens-awl-stl-programmer
Generate Siemens S7-300/S7-400/S7-1500 Statement List (STL/AWL) programs compatible with Step7 Classic and TIA Portal. Use this skill whenever the user asks to write, generate, create, or modify any PLC logic, function blocks, organization blocks, data blocks, or control programs in STL/AWL format. Also trigger for any questions about Siemens S7 memory addressing, timers, counters, accumulators, block structure, or Step7/TIA Portal imports. Always use this skill even if the user just mentions "STL", "AWL", "Step7", "TIA Portal", "S7-300", "S7-400", "S7-1500", "PLC block", "OB", "FB", "FC", or "DB".
DeepseekModel
官方收录技能
质量 良好 · 48
v1.0.0
获取
https://deepseekmodel.com/api/download.php?id=chewcw-agent-skills-siemens-awl-stl-programmer-skill-md&format=skill
下载 .skill
标准格式,含 system_prompt 与 model_config,导入任意 Agent 框架即可使用
.skill 文件中 system_prompt 字段的实际内容。
name siemens-awl-stl-programmer description Generate Siemens S7-300/S7-400/S7-1500 Statement List (STL/AWL) programs compatible with Step7 Classic and TIA Portal. Use this skill whenever the user asks to write, generate, create, or modify any PLC logic, function blocks, organization blocks, data blocks, or control programs in STL/AWL format. Also trigger for any questions about Siemens S7 memory addressing, timers, counters, accumulators, block structure, or Step7/TIA Portal imports. Always use this skill even if the user just mentions "STL", "AWL", "Step7", "TIA Portal", "S7-300", "S7-400", "S7-1500", "PLC block", "OB", "FB", "FC", or "DB". metadata {"version":"1.0"} Siemens S7 STL (AWL) Programming Skill Overview Generate Siemens S7-300 / S7-400 / S7-1500 Statement List (STL / AWL) programs compatible with Step7 Classic and TIA Portal . Core model knowledge: Accumulator-based execution (ACCU1 / ACCU2) RLO (Result of Logic Operation) for boolean logic S5 timers, IEC timers (TON/TOF/TP), counters, INT and REAL arithmetic OB / FB / FC / DB block hierarchy Standard scan cycle model (Read → Execute → Write) For full instruction syntax, see references/STL_Core_Instructions.md . Critical Rule: Omit Block Number ( NAME ) Line Always omit the NAME : '<number>' line unless the user specifically requests a fixed block number. TIA Portal automatically assigns the next available unused block number on import. Block Structure Organization Block (OB) ORGANIZATION_BLOCK "OB1" TITLE = Main Program Cycle { S7_Optimized_Access := 'TRUE' } VERSION : 0.1 VAR_TEMP TempVar : Int; END_VAR BEGIN NETWORK TITLE = Example Network L PIW256; T #TempVar; END_ORGANIZATION_BLOCK Function (FC) — Stateless FUNCTION "FC_Name" : Void { S7_Optimized_Access := 'TRUE' } VERSION : 0.1 VAR_INPUT IN : Int; END_VAR VAR_OUTPUT OUT : Real; END_VAR BEGIN NETWORK TITLE = Convert and Scale L #IN; ITD; DTR; T #OUT; END_FUNCTION Function Block (FB) — Stateful FUNCTION_BLOCK "FB_Name" { S7_Optimized_Access := 'TRUE' } VERSION : 0.1 VAR_INPUT StartPB : BOOL; StopPB : BOOL; END_VAR VAR_OUTPUT MotorOut : BOOL; END_VAR VAR RunLatch : BOOL; Delay : TON; END_VAR BEGIN NETWORK TITLE = Start Latch A #StartPB; AN #StopPB; S #RunLatch; NETWORK TITLE = Output A #RunLatch; = #MotorOut; END_FUNCTION_BLOCK Data Block (DB) DATA_BLOCK "DB_Name" { S7_Optimized_Access := 'TRUE' } VERSION : 0.1 NON_RETAIN VAR Value : Int; END_VAR BEGIN END_DATA_BLOCK Key Formatting Rules Always include { S7_Optimized_Access := 'TRUE' } after block keyword Use symbolic quoted names ( "BlockName" ) — never numeric references Prefix local variables with # (e.g., #StartPB ) Each instruction ends with ; Use NETWORK + TITLE = ... + // comment for each logical group Timer Selection: Inside FC: Use S5 timers ( SE , SP , SD , SA , SS ) Inside FB: Use IEC timers ( TON , TOF , TP ) Code Generation Constraints MUST: Use symbolic quoted names for all block references Generate complete, compilable blocks Separate logical groups into individual NETWORKs Use uppercase STL mnemonics (A, AN, O, =, S, R, L, T, FP, ITD, DTR, etc.) Generate matching instance DB when generating an FB MUST NOT: Mix LAD, SCL, or non-STL syntax Use numeric-only block references unless user explicitly requests Include NAME : '<number>' in generated blocks When to Consult Documentation If the user's request involves instructions or patterns not covered here , consult: TIA Portal STL Reference: https://docs.tia.siemens.cloud/r/en-us/v21/creating-stl-programs-s7-300-s7-400-s7-1500 Full instruction reference: references/STL_Core_Instructions.md Block templates: references/REFERENCE.md Formatting rules: references/FORMATTING.md Typical cases requiring documentation lookup: Interrupt OBs (OB35, OB40, OB80) and their startup VAR_TEMP System function calls (SFC, SFB) such as CALL SFC14 String handling, DATE_AND_TIME types BLKMOV , FILL , UBLKMOV block move instructions Less common accumulator operations ( CAD , CAW , TAK , PUSH , POP )
Agent 识别该技能的关键词,点击任意一个即可复制。
该技能未提供触发词。
下载的 .skill 包内含以下字段。
| 字段 | 说明 |
|---|---|
| format | 格式标识(skill/v1) |
| skill_id | 技能唯一 ID |
| name | 技能名称 |
| version | 版本号 |
| description | 技能描述 |
| category | 所属分类(数组) |
| trigger_words | 触发词列表 |
| tags | 标签列表 |
| source | 来源标识 |
| source_url | 来源链接(本页地址) |
| exported_at | 导出时间(每次下载生成) |
| system_prompt | 系统提示词正文 |
| model_config | 模型参数:provider / model / temperature / max_tokens / top_p |
| examples | 示例 |
| install_guide | 各平台导入说明(Coze / Dify / Claude / 自定义框架) |